High Voltage Test and Measuring equipment (AC Test Set)100kV,100kVA

 

Consisting of:

SL NO DESCRIPTION TYPE QTY
1 HV Test Transformer Pri. 400 V, 50Hz, Sec. 100kV, 50kVA continuous 100kVA 1Hr.on,23Hrs. off Partial Discharge < 5 pC upto rated voltage (100 kV) TEO100/100 1
2 Control Desk (Motorised) with oil cooled Auto Transfer CD 20 1
3 Capacitor (Coupling / Measuring) 100kV, 100 pF PD < 5 pC CM100-S 1
4 Voltmeter (AC peak--- 4.5 Digit, Digital Display) DSM 1
5 Flexible connecter HSV 1
6 Compensating Reactor DEL 100-T 1

Pre-despatch Tests at our Works on No-Load :

Sr.No HV Transformer (Type TEO 100/100) Capacitor (Coupling / Measuring) Type CM 100-S
a No-Load and short circuit Tests HV withstand Test at 120 kV, 50Hz, for 1 minute
b HV withstand Test at 120 kV, 50 Hz, for 1 minute Measurement of Capacitance and Tan at 20% Voltage intervals us to rated Voltage (100 kV)
c 5 flashover Tests at 100 kV Measurement of Partial Discharge at 20% Voltage Intervals up to rated Voltage (100 kV)
d Partial Discharge Test before and after the Test (b) and (c) at 20% Voltage Intervals.